Control panels

Motor starters, variable speed drives and multi-drive panels, built to order.

What it is

Wall-mount and floor-standing panels built at Wakefield, wired to a schedule and tested before they leave. Standard designs from a direct-on-line starter up to a 2000 A multi-drive panel with a PLC rack — and if none of them fits, we will build to your schematic rather than talk you into one that nearly does.

What it is not

We do not write PLC application software. We will wire, terminate, test and certify the panel, and we will fit your controller into it — but the program is yours or your integrator’s.

Specification

7 models

ERPNext item group Finished Goods - Control Systems. These are the part numbers on the works order.

Control panels — models, ratings, connections and weights
PartModelRatingConnectionWeight
FG-017Starter MSP-22DOL · 2.2 kW · IP54Wall mount · MCB, contactor, overload12 kg
FG-018Starter MSP-55Star-delta · 5.5 kW · IP54Wall mount · MCCB, dual contactor, timer28 kg
FG-019Drive VSD-22VFD · 2.2 kW · IP54Line choke, EMC filter, local controls18 kg
FG-020Drive VSD-55VFD · 5.5 kW · IP54, floor standingLine reactor, EMC filter, bypass contactor55 kg
FG-001Panel CP-500500 V · single starter · IP54MCB overload, local/remote14 kg
FG-002Panel CP-10001000 V · dual starter · IP54PLC interface, HMI cutout35 kg
FG-003Panel CP-20002000 A bus · IP42, floor standingMCCB incomer, VSD sections, PLC rack120 kg

Materials

  • Mild steel enclosures, powder coated RAL 7035
  • IP54 as standard; IP42 on the floor-standing CP-2000
  • Stainless or GRP enclosures to order

Options

  • Touchscreen HMI
  • Bypass contactor on drive panels
  • Remote I/O and Modbus or Profibus gateway
  • Form 2 or Form 4 segregation
  • Build to your own schematic

In service

Where this range is used

Application notes rather than case studies — we do not name customers without asking, and most would rather we did not.

Pumping station upgrade

A pair of VSD-22 panels and a duty/standby controller is the commonest retrofit we ship — usually replacing two direct-on-line starters that have been hammering the mains and the pump bearings for twenty years.

Process line control

The CP-1000 carries a PLC interface and an HMI cutout as standard, so an OEM can drop in their own controller and their own software without asking us to modify a panel design.

Sectors this range serves

  • Water & wastewater

    Our largest sector, and the one we have been in longest.

  • Food & beverage

    Stainless, cleanable, and documented.

  • Energy & utilities

    Generation, district heating and grid-adjacent plant.

  • OEM & systems integrators

    Our components inside somebody else’s machine.

All sectors we supply

Ask us about control panels

Send the duty and we will tell you which model fits, or that none of them does.