Products
Sensors & instrumentation
Temperature, pressure and flow measurement, plus the housings to field-mount it.
What it is
Process instrumentation with a 4–20 mA output and no proprietary protocol in sight. We keep the range small on purpose: three measurements, done properly, plus two enclosure sizes for mounting transmitters where the weather is.
What it is not
None of these are custody-transfer or fiscal-metering instruments. Where the measurement is the basis of a payment, you need an approved meter with the paperwork to match.

Specification
5 models
ERPNext item group Finished Goods - Sensors. These are the part numbers on the works order.
| Part | Model | Rating | Connection | Weight |
|---|---|---|---|---|
| FG-012 | Temperature TS-100 | PT100 RTD · −50 to 400 °C | 200 mm immersion, 6 mm dia · 4–20 mA | 0.35 kg |
| FG-013 | Pressure PS-200 | 0–10 bar · IP67 | G½ · 4–20 mA / HART | 0.45 kg |
| FG-014 | Flow FS-300 | Electromagnetic · DN50 | Flanged · 4–20 mA, pulse, Modbus | 8.5 kg |
| FG-015 | Housing SH-100 | IP67 · 120 × 80 × 60 mm | Cast aluminium, glands pre-drilled | 0.8 kg |
| FG-016 | Housing SH-200 | IP68 · 150 × 100 × 80 mm | Cast aluminium, double-sealed entries | 1.2 kg |
Materials
- Stainless steel wetted parts on the PS-200
- PTFE liner with stainless electrodes on the FS-300
- Cast aluminium housings, powder coated
Options
- Head-mounted or rail-mounted transmitter
- Extended immersion lengths on the TS-100
- Thermowell to suit the process connection
- Factory calibration certificate traceable to national standards
In service
Where this range is used
Application notes rather than case studies — we do not name customers without asking, and most would rather we did not.
Final effluent monitoring
The FS-300 with a PTFE liner handles the aggressive, dirty and intermittent flows that defeat a turbine meter, and its Modbus output drops straight into an existing telemetry outstation.
Pasteuriser and vessel temperature
The TS-100 in a thermowell is the standard fit on hot-fill and pasteurisation lines, where the ability to pull the element without draining the vessel matters more than the last 0.1 °C.
Pump protection
A PS-200 either side of a strainer is the cheapest differential-pressure alarm you can fit, and it will tell you a basket is blinding long before the pump cavitates.
Sectors this range serves
Water & wastewater
Our largest sector, and the one we have been in longest.
Food & beverage
Stainless, cleanable, and documented.
Chemical & process
Where the fluid is trying to destroy the equipment.
Energy & utilities
Generation, district heating and grid-adjacent plant.
Other ranges
Ask us about sensors & instrumentation
Send the duty and we will tell you which model fits, or that none of them does.